Rain CII's main Laboratory
is located in Lake Charles,
Louisiana. It has a second
smaller lab in Moundsville,
West Virginia. The Laboratory
performs analyses of samples of all raw materials, the calcined coke
product produced at each plant, and all customer shipments. Standard
chemical and physical properties of all our products are analyzed using industry-accepted
procedures under a rigorous quality assurance program.
Green and calcined petroleum cokes can be analyzed for the following
properties using the procedures designated:
|
Property
|
Green Procedure
|
Calcined
Procedure
|
|
Moisture
|
ASTM
D4931
|
ASTM
D4931
|
|
Ash
|
ASTM
D4422
|
ASTM
D4422
|
|
Volatile
Matter
|
ASTM
D6374
|
N/A
|
|
Sulfur
|
ASTM
D6376
|
ASTM
D6376
|
|
Metal
Impurities
Si, Fe, V, Ni, Ca, Na
|
ASTM
D6376
|
ASTM
D6376
|
|
Specific
Resistivity
|
N/A
|
GLC
C-12A
|
|
Real
Density
|
N/A
|
ASTM
D2638
|
|
Vibrated
Bulk Density
|
N/A
|
ASTM
D4292
|
|
Screen
Size
|
ASTM
D5709
|
ASTM
D5709
|
|
Air
Reactivity
|
N/A
|
ISO
12982-1 (600 °C @
10 °C /min)
|
|
Co2
Reactivity
|
N/A
|
ISO
12981-1
|
|
Crystallinity
Index (Lc)
|
N/A
|
ASTM
D5187
|
|
Dedust
Oil Content
|
N/A
|
300
°C for 3 hours
|
Contact us if you need coke analyses performed under a well-defined quality
assurance program.
^TOP
|